Fire risk assessments tailored to your premises.

Every building has different fire safety requirements. Our assessments consider the specific characteristics of each premises, with attention to the risks associated with its layout, occupancy and use.

A mill office landing with a glazed fire door held open by a wedge.

Blocks of flats and HMOs

Fire safety assessments covering communal areas, escape arrangements and relevant fire precautions in residential buildings.

A shared landing with a bicycle and scooter against the wall and a flat door without a closer.

1

Storage within communal areas

Potential obstruction

Items stored in communal circulation areas should be assessed for their potential impact on escape routes and fire safety.

2

Flat entrance door

Fire door arrangements

Relevant flat entrance doors are considered as part of the assessment, including their condition and self-closing arrangements.

What we assess

Communal escape routes, stairways and final exits.

Flat entrance doors, self-closing devices and visible fire protection measures.

Fire detection, warning systems and emergency lighting, where applicable.

Storage arrangements, service cupboards and potential fire hazards.

Fire safety management, maintenance records and relevant procedures.

Assessment scope

Determined by the building's size, layout and fire safety arrangements.

Shops and retail premises

Fire risk assessments for retail environments, including customer areas, storage facilities and staff accommodation.

A small shop floor with a stockroom door propped open and a clear aisle to the fire exit.

1

Storage area

Housekeeping arrangements

Storage should be organised to maintain safe access and prevent obstructions to designated escape routes.

2

Fire door

Door operation

Fire doors should remain effective and must not be obstructed or held open without an appropriate device.

What we assess

Escape routes and final exits available to staff and customers.

Storage arrangements and the management of combustible materials.

Fire doors and measures intended to restrict the spread of fire.

Electrical equipment, lighting and other potential ignition sources.

Fire detection, emergency procedures and staff responsibilities.

Assessment scope

Determined by the size, layout and operational requirements of the premises.

Offices

Fire safety assessments for workplaces, considering building arrangements and the needs of employees and visitors.

An empty open-plan office with a lead across the aisle and an exit door partly blocked by boxes.

1

Electrical cabling

Potential hazard

Cables and extension leads should be appropriately managed to reduce fire and trip hazards.

2

Obstructed exit route

Action required

Furniture, equipment and stored materials must not compromise the safe use of designated escape routes.

What we assess

Workplace escape routes, stairways and final exits.

Fire doors and relevant compartmentation measures.

Electrical equipment, cabling and potential ignition sources.

Fire detection, warning systems and emergency lighting.

Evacuation procedures, staff information and fire safety management.

Assessment scope

Reflects the building's size, occupancy and workplace arrangements.

Schools and educational premises

Fire safety considerations for educational buildings, taking account of pupils, staff and the organisation of the premises.

A school corridor with a classroom door propped by a bin and paper artwork covering the wall.

1

Corridor storage

Escape route considerations

Storage within circulation areas is assessed to establish whether it affects the safe use of designated escape routes.

2

Wall displays

Combustible materials

The extent and positioning of combustible displays are considered in relation to the corridor's use as an escape route.

What we assess

Escape routes and exits serving classrooms and communal areas.

Fire doors, compartmentation and relevant protective measures.

Fire detection, warning systems and emergency lighting.

Evacuation procedures and arrangements for pupils requiring assistance.

Fire safety management, staff responsibilities and maintenance arrangements.

Assessment scope

Reflects the building's layout, pupil numbers and operational requirements.

Care homes

Fire safety assessments for residential care environments, with particular consideration for occupants who may require assistance during evacuation.

A care home corridor with a bedroom door held open by a chair and a laundry trolley parked in the route.

1

Furniture in corridor

Escape route considerations

Furniture positioned within corridors should be assessed to ensure it does not obstruct movement or interfere with evacuation arrangements.

2

Linen trolley

Combustible storage

The positioning of linen trolleys should be considered in relation to fire loading and the protection of designated escape routes.

What we assess

Escape routes and arrangements for assisted evacuation.

Fire doors, compartmentation and measures to limit fire spread.

Fire detection and warning arrangements appropriate to the premises.

Evacuation strategies and relevant resident support requirements.

Fire safety management, staff training and maintenance records.

Assessment scope

Reflects the building's characteristics, resident needs and evacuation arrangements.

Hotels and hospitality

Fire safety assessments for accommodation and hospitality premises, considering the needs of guests, visitors and staff.

A hotel corridor with a fire door missing its closer arm and linen stacked on the floor.

1

Fire exit arrangements

Means of escape

Escape routes and final exits are considered in relation to their accessibility and suitability for occupants.

2

Corridor storage

Potential obstruction

Stored materials should not compromise escape routes or interfere with relevant fire safety measures.

What we assess

Escape routes, stairways and final exits serving guest accommodation.

Bedroom fire doors and relevant compartmentation measures.

Fire detection, warning systems and emergency lighting.

Fire precautions associated with kitchens and other operational areas.

Emergency procedures, staff responsibilities and arrangements for guests requiring assistance.

Assessment scope

Reflects the premises' size, occupancy and operational arrangements.

Every building is different. Let's discuss yours.

Tell us a little about your premises and what you need. We'll review your requirements and provide a clear, fixed-fee quotation.